Question
· Nov 30, 2023
Multitransformations of HL7

This question originally appeared in the comments of the post: Making use of Multiple Sub Transforms in a main map || HL7

I'm having a similar problem trying to get PRD(1) into PV1:ReferingDoctor and PRD(2) into PV1:ConsultingDoc

Running the subtransform will populate referring doctor for the first PRD, and then the second running will delete the PV1, make a new one with only the consulting doctor populated.

0 1
0 191
Question
· Nov 20, 2023
HL7 field for base64 in orl

Hi everyone,

It could be great if some of you have had experience in hl7 v2 messages. The question is about FHIR to hl7 v2.5 conversion. I have to translate a binary resource, encoded in base64 into an orl_o22 message. Do you have advices? Which field could be used for that datatype?
I have found some implementation using nte segment but it is limited in characters.

Thank you

0 5
0 288

Good morning,

First of all we would like to thank you for your time reading, thinking and aswering this question.

We have been developing a Transformation to convert a source ORU_R01 to a target ORU_R01. For each OBX segment we need to check an if, and then, if it is true we just need to put this OBX and continue to the next iteration, otherwise, if it is false, we need to put (copy) the ORC + OBR + TQ1 before this OBX, and then put this OBX, and after that, the SPM.

0 4
0 236

Hello,

First of all, thanks for your help, and time, reading this questions, and answering to this doubt.

We have the following use case: to convert a HL7 ER7 ORU_R01 v2.5 message, to a Ens.Request Message which represent it with a custom data structure (each segment is a group of Properties).

To be more precise, the target Ens.Request Message's structure looks like:

0 5
0 472

Hello,

I have a problem attempting to store a base 64 encode stream into the OBX:5 field of a HL7 message, by using the StoreFieldStreamBase64 method.

I'm using a transformer to input the contents of a pdf within a stream container (Ens.StreamContainer). The output is a HL7 message (EnsLib.HL7.Message 2.5:ORU_R01).

The transformer is being used in a business process.

This is the code used in the transformer to encode the stream to base 64:

0 2
0 389
Question
· Jul 3, 2023
HL7 test message generator

I am looking for an appropriate solution to generate HL7 test messages to test my production. IRIS for Health already contains many HL7 specific functions like the schema structures. Furthermore one can use transformations to build custom messages.

What I am interested in is if anyone has already created a tool or script that can be used to create any HL7 messages that meet the minimum requirements and populate all the required fields with test values. I would then like to send these test messages via TCP to a business service.

3 12
2 2K

Hi,

I have a ORU message, which has a EVN segment that I want to remove and send the message across.

I tried to clone the request as below:

s newreq = request.constructClone

s changreq = newreq.RemoveSegmentAt("EVN")

Set request = changereq

but it fails. Is there a way that I can safely remove a segment and pass it on?

Would appreciate your help in this

Regards,

Eric

0 13
0 1.9K

We have this intermittent issue with a particular supplier message , just wondering if anyone has further insight around the two errors we get when we see this.

We use the out of the box TCP hl7 adapter.

We first seem to get this incomplete hl7 message resulting in an error like

Discarding leftover input 'MSH|

This is not unexpected as the final obx has not dot the description of OBX:2.2 ect.

OBX|53|TX|NCDAC^

The next message will have the error

0 2
0 205

If you hold the InterSystems HL7 Interface Specialist certification, you can potentially get recertified and have your certification expiration date extended by five years by beta testing our new InterSystems HL7 Interface Specialist Recertification project. The project includes hands-on exercises to validate core skills for developers who use InterSystems products to build and test HL7 v2.x productions.

1 0
2 149

Greetings.

I have a scenario in ENSEMBLE, where a business process router A is dependent on another business process router B. If B shuts down for some reason, A has to be disabled as well.

Do i need to write a custom process for B and call the call back method onShutdown or something?

Any suggestions would be appreciated.

Thanks,

Jimmy Christian.

0 0
0 114

I have been successfully able to transform hand-written medical test results documents to HL7 ORU_R01 v2.x, then to SDA, which will be trasformed to FHIR or C-CDA.

However, I have a category of documents which contains reference range in multiple date formats, which are measured for each gestation period.
For example, below is one of the documents.

Analyte: HCG, Value: 1968, Unit: mlU/mL

0 4
0 246
Question
· Jul 27, 2023
Rule logic

In an HL7 Business rule I am trying to block ONLY ORM messages that have a PV1:3.4 of 105 or 205 and a OBR:4 value of EP22 or CATH01.

I created the logic below but it appears to be evaluating the two fields independently instead of combined?

Here is what I had.

0 1
0 189

How to import Custom Schemas from VSCode? They look like this:

<?xml version="1.0"?>
<Category name="ITK" description="xmlns:hl7='urn:hl7-org:v2xml' xmlns:xsi='http://www.w3.org/2001/XMLSchema-instance'" std="1">
<MessageType name='ACK' structure='ACK' returntype='ACK' description='xsi:schemaLocation="urn:hl7-org:v2xml ACK.xsd"'/>
</Category>

Instead of wrapped XML export produced by $system.OBJ:

0 2
0 264

Written in reply to community post for can Python create HL7 Message dynamically.

Pre-requisites and setup

Use an integration enabled namespace.
Note: USER namespace is not enabled for interoperability by default.
If following suggest create a new interoperatibility namespace to explore functionality.

# Switch to
ZN "[Interoperability Namespace Name]"

# Launch interactive Python shell:
Do $SYSTEM.Python.Shell()

4 0
2 464

Hello Community,

The Certification Team of InterSystems Learning Services is excited to announce the release of our new InterSystems HL7® Interface Specialist exam. This is an updated and rebranded version of our previous HL7 exam, formerly know as HealthShare Health Connect HL7® Interface Specialist. It is now available for purchase and scheduling in InterSystems exam catalog. Potential candidates can review the exam topics and the practice questions to help orient them to exam question approaches and content. Candidates who successfully pass the exam will receive a digital certification badge that can be shared on social media accounts like LinkedIn.

5 0
0 195

Hi all,

I'm wondering if is possible to call to a BO from a HL7 Route according to a parameter of the HL7 Message

I mean,

According to the identify of the laboratory, I want to call to other TCP process to retrieve information about blood tests.

We are creating the BO using this partern.

LAB.BO.TCP. + name of the laboratory.

The name of the laboratory is stoted in the lookup table T_LABORATORIOS

I've tried to assign the name into a variable and put it in the "send" instruction, but it doesn't work.

1 3
0 216