Question
· Jul 17, 2017
Purge for "IO Log Input Data"

Hello mates,

When turning on the “Archive IO” option within the business operations, it provides us the capability of seeing the input and output communication with external systems. For instance, watching the messages sent out + ACK message sent back .

Our production has got a scheduled task that runs daily (by default I guess, as many others) and is in charge of purging “Errors and log files”. And this is likely to be linked to the “Archive IO” feature, right?

0 2
0 536

Ensemble 2015. Working on an a way to send NACK'd HL7 messages to a flat file for external review/troubleshooting. (Similar to the way BadMessageHandler deals with validation errors.)

I think I have the Alert piece down, but need assistance with the exact syntax to do an SQL query in the DTL (or a custom function) to pull the HL7 message Raw Content into the Alert, based on the SessionID.

(Also, anything special to write alerts to the File Operation?)

Thanks, Brian

0 3
0 868

Hello,

I have been struggling and could use some help as I think I'm burnt. I am trying to change a Textual 2.5.1 OBX;5 with multiple iterations to a simple non-iterating outbound result. I have played around with $piece but can't seem to get it to work. The outcome I would like is for OBX;5 to look like this: |Positive| and currently it looks like this: |Positive~_~_~_~_~|. Any suggestions would be appreciated.

0 3
0 464

Is there a way to use a HL7 field value as part of the File Naming in the Business Operation FileOperation class. I know we can do this in a custom class, but I was wondering if it could be done the default FileOperation class?

Example:

MSH-4 contains the value 12345

We would like to name the file 12345_YYYYMMDDHHMMSS.HL7

MSH.4 value here_%Y%m%d%H%M%S.HL7

It may not be possible, but I just want to see if anyone has any information

Thanks,

Kevin Brown

0 3
0 816

Suppose I have an image and need to convert that image into a PDF for inclusion in an HL7.

I know that Zen Reports can display an image in a PDF but I do not want to view the image in a web page. I just need to convert the image to PDF in a Process and then include that PDF in an HL7. The workflow would be like this:

Get image -> Convert image into PDF -> Include PDF in HL7 OBX.

I know how to do the last part to include PDF in HL7 OBX. Just need ideas on the first part.

0 2
0 1.2K

Folks

1) What's the correct way to check for an existence of a segment? So far I have been doing this by checking to see if a required field is non-null, and this seems to work but is a bit clumsy. In this case, it’s an X12 message being checked in an IF action in BPL:

request.GetValueAt("NTE(1):Description")'=""

Or in a DTL, to see if a Z segment exists:

source.{ZEF:Counter}=1

0 3
0 1.5K
Question
· Apr 12, 2017
Message Profiling

Hi all,

I was wondering if InterSystems offers any message profiling capabilities. What I mean by "message profiling" is essentially stats or metrics gathered from a collection of data submissions of a particular type. For instance, average number of segments <XYZ> in a specific HL7 V2 message type. Or the number of sections found in a HL7 V3 CDA documents.

Curious if there is anything like this provided "out-of-box".

Thanks!

James

0 4
0 421
Question
· Mar 16, 2017
HL7 Service - design question

noob here..(moving from JCAPS to Ensemble)

We are wondering where is the best place to tie the schema category for an incoming HL7 message? Should we do this within the service (via the message schema category setting) or receive everything and validate in the process (DTL) level?

We want to capture everything that will be sent to that HL7 listener service and then decide what to do with bad messages at the process layer.

Does anyone have any recommendation regarding this? Appreciate your input and decision thought process.

Thank You,

0 3
0 336

Hi,

We have a mixture of legacy and new systems, and are grappling with the issue of moving documents between systems.

At the moment we are mostly using file drops and encoding metadata in filenames, but a new supplier (letter transcription) is going to provide a Hl7v2 feed sending MDM^T02 messages with PDF's of letters base64 encoded in the message itself.

We are thinking of asking all our suppliers to go with MDM (or ORU) for sending documents.

I'm interested in the pros and cons of the options; and if there are options I haven't thought of.

0 2
0 711
Question
· Mar 3, 2017
Large HL7 Batch

Hi

I need to process a very large Batch file which contains HL7 charges which we pull using FTP. I need to loop through the file and do some checks and then split the large Batch file in to individual messages. These individual messages then gets process through a different module to create a output batch of different format

0 3
0 762

Hi all,

We have a big problem with spanish accent and special characters using Data Transformation (HL7 Messages).

We have some DT to transform HL7 messages to other type (OUL^R22 To OML^O21) so it copys the PID segment to the new one, but if in the PatienName field has any special character, the transformation stops and it not continues with the transformation.

This is the message

2 1
0 1.1K

For testing purposes, I would like to create an EnsLib.HL7.Message from either a %String or a file on disk and pass it into a function in a unit test (outside of an Ensemble context). EnsLib.HL7.Parser appears to do the necessary parsing, but it also sends the message via Ensemble service rather than returning it as a value. Is there a way to leverage the parsing outside of a Ensemble service? Alternatively, is there another way to create an EnsLib.HL7.Message?

1 4
0 3.2K
Question
· Dec 8, 2016
JSON to HL7

I have a project to convert a JSON message with two patient identifiers into an HL7 ADT^A31. Is there any documentation or training that you would think is appropriate?

Currently using Ensemble 2014.1.5 on AIX

0 1
0 2.5K

Hopefully somebody can help with this :

Using healthshare - Ensemble::: I have an HL7 message (ORU^R01) where I have an RTF file embeded into an OBX segment as what appears to be plain text.

example below :

How would I extract this file out and create an email and attach this RTF file as an attachment?

0 2
0 813

We are interfacing through Ensemble with an application that does not like diacritic signs in text. I have been searching for a way to strip these signs from the HL7 messages that get send to that application.
The problem in short is we have an incoming HL7 message with e.g. é (or ë, á etc), this goes into Ensemble. In the outgoing message the é should be replaced with an e.

2 1
0 447

I'm trying to read PID-3 and route the message based on if a certain prefix existed, but I keep getting Property Does Not Exist.

I've tried

HL7.(PID:PatientIDInternalID()) Contains "COS"

HL7.(PID:PatientIDInternalID(1)) Contains "COS"

HL7.{PID:PatientIDInternalID()} Contains "COS"

HL7.{PID:PatientIDInternalID(1)} Contains "COS"

This is a 2.3 MDM message. Thanks!

0 1
0 571
Article
· Sep 20, 2016 4m read
Diagnosing Framing Errors

Framing refers to the characters that mark the start and end of an HL7 message (or other types of framed messages). Most HL7 services and operations have a Framing setting that allows the user to define this framing. The most common choices are available as defaults, but with the AsciiMM/NN setting, components can be configured to recognize any framing characters.

4 0
2 2.5K