In a Business Process using the %PrimaryRequestHeader I can call GetAdapterSettingValue and get the setting from a Business Service. But once I am in the Business Operation there is no class for %PrimaryRequestHeader. Is there another way to get setting in the Business Operation that was define in the Business Service ?
Set tSrcCfg = ..%PrimaryRequestHeader.SourceConfigNameIf tSrcCfg '= ""{ Set tCfgVal = ##class(Ens.Director).GetAdapterSettingValue(tSrcCfg, "OutboundFilePath", .tSC) $$$LOGINFO(tSrcCfg _ ", Outbound FilePath: " _ tCfgVal) s tPath = tCfgVal}