#Ensemble

0 Followers · 2.3K Posts

InterSystems Ensemble is a complete and easy-to-use integration platform that enables users to connect people, processes, and applications in record

time.

Learn more

Documentation

Question Gigi La Course · Sep 9

I have a vendor that only wants results on patients that arrive to the ED via EMS/Ambulance.  The value I need for filtering is in the PV2;38. Some of the results requested do not allow the PV2 segment to be added to the schema in the EMR.  I was told that other orgs have used a lookup table that is populated with the PV1;19 value when an ADT messages that meets the criteria is sent in.  This table is then referenced in the business rule for the results that do not have PV2;38 and if Encounter number from result message exists on the Table, the result is sent.  Has anyone done this before?  

0
0 0
Article Victoria Castillo · Mar 19, 2024 5m read

I have been walking through this with a few team members and as such I thought there might be others out there who could use it, especially if you work with HL7 & Ensemble/HealthConnect/HealthShare and never venture out past the Interoperability section. 

First, I would like to establish that this is an extension of the already established documentation on importing and exporting SQL data found here: https://docs.intersystems.com/iris20241/csp/docbook/DocBook.UI.Page.cls?KEY=GSQL_impexp#GSQL_impexp_import

0
0 554
Article Hiroshi Sato · Nov 21, 2024 1m read

InterSystems FAQ rubric

Mirroring only synchronizes database files.

To synchronize other files required for your application (CSP files, images, documents, etc.) between the two servers that make up the mirror set follow one of the approaches:

  1. Place those files on a shared disk by introducing a NAS or similar device
  2. Or use file sync software to synchronize files between two servers.
0
0 0
Question Matheus Augusto · Sep 4

Dear, Community!

I have a concern about using %Stream.TmpCharacter for storage purposes. Reading the class's source code, I can understand a bit about how it works. But I'd like to know from the community how it actually works. Is it necessary to use the .Clear() method to clear this buffer, or is it done automatically upon disposal?

Note: Please forgive my poor English.

0
0 0
Question Anna Golitsyna · Aug 28

Studio's Find In Files finds nothing if CLS routines are included. The error is WIDE CHAR. After using ##class(%Studio.Project).FindInFiles programmatically and then ZW after the same error I strongly suspect that CodeWalkopdatecopyopt in EnsLib.InteropTools.HL7.Cloverleaf.Parser.cls  is to blame. I cannot even open this class, unlike other classes from EnsLib.InteropTools.HL7. This error prevents searching even if System Items are excluded and I would peg EnsLib as System. Any remedy besides updating IRIS? Assuming this is fixed in later IRIS versions.

0
0 0
Question Chris Lambert · Aug 21

Hello,

I'm trying to get the Reply Action Code to work with the error message text.

I have this ACK:

MSH|^~\&|APP|FACIL|||20250821143621||ACK|CUEACK_20250821143621|P|2.4
MSA|AE||Failed to queue message

This is some of the Action Codes I've tried:

  • E*Failed to queue message=S
  • E*Failed=S
  • E*"Failed to queue message"=S
  • :E*Failed to queue message=S
  • :?E*Failed to queue message=S

It's not suspending the message however.

What am I doing wrong?

Thank you

0
0 0
Article Harshitha · Aug 3 2m read

Working in healthcare IT as a young developer, especially on InterSystems TrakCare, you quickly realize one thing: it’s not just about HL7 messages or backend integrations. A hugepart of making TrakCare work smoothly for hospitals comes down to how it’s configured, customized, and supported on the application side.

That’s where people like me come in—techno-functional developers who understand both the tech and how it impacts actual hospital workflows.

We’re Not Just Techies (or Functional Consultants)

Our role sits right in the middle. We're the ones:

0
0 0
Article Henry Pereira · Jul 31 5m read

If you’ve ever watched a true artisan—whether a potter turning mud into a masterpiece or a luthier bringing raw wood to life as a marvelous guitar—you know that magic isn’t in the materials, but in care, craft, and process. I know this firsthand: my handmade electric guitar is a daily inspiration, but I’ll admit—creating something like that is a talent I don’t have.

0
0 0
Article Robert Cemper · Jul 23 1m read

If you are investigating complex structured Globals this can become
a rather boring typing exercise. Different from Global Explorer in
System Management Portal Global-Inspector allows a kind of drill-down
to dig deeper and deeper by subscript levels.
You also have the option to see the stored content or to show only
the subscript structures.
Globals storing SQL Tables are probably not so thrilling, but in SYSTEM
space you find real trees with completely different branches and twigs.

Global-Inspector can run in browser or from terminal command line.

required input

0
0 0
Question Dustin Knudsen · Jun 7, 2021

One of the business operations recently errored out, and keeps spitting this message:

ERROR <Ens>ErrFailureTimeout: FailureTimeout of 15 seconds exceeded in EnsLib.FTP.PassthroughOperation; status from last attempt was 
ERROR <Ens>ErrOutConnectFailed: SFTP Connect failed for ftp.[censored].com:2222/[censored]/SSL='!SFTP'/PubKey='C:\InterSystems\HealthShare\Keys\pub\[censored]'/PrivKey='C:\InterSystems\HealthShare\Keys\priv\[censored].pem'
with error ERROR #7500: SSH Connect Error '-2146430963': SSH Error [8010100D]: Failed getting banner [8010100d] at Session.cpp:238,0 (alert request ID=45956)

1
0 350
Article Mihoko Iijima · Oct 3, 2024 3m read

InterSystems FAQ rubric

You can check the free disk space at any time using the system utility class: SYS.Database and query: FreeSpace.

Here's how to try it in the IRIS terminal (go to the %SYS namespace and then run it):

zn"%SYS"set stmt=##class(%SQL.Statement).%New()
set st=stmt.%PrepareClassQuery("SYS.Database","FreeSpace")
set rset=stmt.%Execute()
do rset.%Display()

The output result example is as follows:

*In the command execution example, all databases are located on the same disk, so the free disk space (DiskFreeSpace) returns the same value.

0
0 0
Question Colin Brough · Jul 9

When accessing management portal through IIS the page is not fully rendered and the buttons/links that are displayed don't work.

Management Portal works fine through private web-server.

Have just set up IIS/CSP Gateway to access Ensemble, and accessing the CSP Gateway configuration pages through IIS works fine (screenshot at end of post).

This is the view when accessing management portal through IIS (port 80) - missing images, links don't work, not all content displayed:

And this is the (top of the) view when accessing through the PWS (port 57772):

0
0 0
Question Colin Brough · Jul 1

Is it possible to audit code changes in a namespace?

Ideally what we'd like to be able to do is check which classes were compiled (or deleted) in a time period, eg in last 3 months, and which user made those changes. Even better would be an audit of what those changes were, but that's less important (for us, as we can probably find that information in other ways).

0
0 0
Question Colin Brough · Jun 26

I am attempting to follow the tutorial at Publishing Web Services Using Caché | Caché Web Services QuickStart Tutorial | Caché & Ensemble 2018.1.4 – 2018.1.11 to build a toy SOAP web-service using Cache but am running into what I suspect are permissions issues, or perhaps setting up the "plumbing" to get an incoming request to call the web-service methods.

Ensemble instance running on local laptop. Only the Ensemble private web-server installed on the machine (no IIS or Apache).

0
0 0
Article Liam Evans · Jun 18 3m read

My intention is to show how simple it is to generate a lookup table taking into account the information received in our HL7 messaging. The HL7 message lookup table provided by IRIS is certainly sufficient for most of the searches we want to perform, but we always have that special field in our HIS, LIS, RIS, etc. that we'd like to search by. But that's in a segment outside of that lookup table. That field forces us to generate a specific search using the expanded search criteria. We'll likely have many messages, and we'll also have to filter by date and time so we don't timeout.
 

0
0 0
Question Justin Ruggles · Jun 17

I am trying to add a value to my concatenation string and the value is not being inserted in the right place. I am adding onto this code from another developer and cannot seem to get it to work. The only code I have added is underlined in bold red.

This is how the translated HL7 message looks:

OBX|1|CE|CDX^History||Specimen 1 Clinical History: CLINICAL HISTORY\.br\\.br\Specimen 2 Clinical History: CLINICAL HISTORY 2\.br\Specimen 1 Suspected Clinical Diagnosis\.br\Specimen 3 Clinical History: HISTORY 3\.br\Specimen 2 Suspected Clinical Diagnosis

This is how it should look:

0
0 0
Article Guillaume Rongier · Apr 9, 2019 3m read

IRIS and Ensemble are designed to act as an ESB/EAI. This mean they are build to process lots of small messages.

But some times, in real life we have to use them as ETL. The down side is not that they can't do so, but it can take a long time to process millions of row at once.

To improve performance, I have created a new SQLOutboundAdaptor who only works with JDBC.

BatchSqlOutboundAdapter

Extend EnsLib.SQL.OutboundAdapter to add batch batch and fetch support on JDBC connection.

Benchmark

Benchmarks released on Postgres 11.2 with 1 000 000 rows fetched and 100 000 rows inserted on 2 columns.

10
3 1851
Question Satya Prasad Kalam · May 30

We're planning to use Production Validator for validating our system upgrade (2016.2.3 to 2024.2) , and we are trying to understand what kind of benchmarking or performance metrics others have observed during similar efforts.

Specifically, we are looking for a case study or real-world example that includes details like:

  • How many messages were validated?
  • How long did it take to create the temporary database from the source system?
  • How long did it take to run the comparison on the destination system?
0